EXHAUST GAS HEAT EXCHANGER STANDARD / OPTION LIST

  • 304L/316L Stainless steel tubes, tube sheet, and header box
  • Shell material of HRCS, 3/16", ASTM A285

Sample Application - A 30kW MicroTurbine

Exhaust Side:

  • Exhaust back pressure less than 3" water column
  • Design Heat Transfer of 250,000 Btu/hr

Coolant Side:

  • Maximum design pressure of 20 PSIG, Factory tested @ 50 PSIG
  • Maximum design fluid flow rate of 30 gpm
  • Maximum pressure drop at design flow rate of 2 PSIG
  • Maximum design fluid capacity of 20.5 US Gallons