ENCLOSED GROUND FLARE STANDARD / OPTION LIST

  • ASTM A-36 Carbon steel flare shell
  • 4" Insulation - 2 layers 8#, 1 layer 4#
  • Ladder assembly with cage and head shield
  • Heat shield
  • Pneumatically actuated shutdown valve assembly
  • Aluminum flame arrestor with upstream and downstream pressure monitoring
  • Burner assembly
  • Automatic air damper assemblies with 4-20mA motor operators
  • Three type K flame monitoring thermocouple assemblies
  • Propane or natural gas pilot assembly including ignition transformer and NEMA 4 enclosure
  • Honeywell UV self checking flame safety system
  • Condensate destruction assembly
  • NEMA 4 junction boxes
  • All wiring pre-installed and pre-conduited to the maximum extent possible
  • Meets UBC 100 mph and seismic zone 4 criteria when properly installed